UV-6000 UV Visible Spectrophotometer

All optical components are fixed on an 8mm thick rigid die-cast aluminum board to promise higher stability and reliability.
Multi-functional PC software is optional.

UV-6100 series UV Visible Spectrophotometer

3 kinds of bandwidth configuration meets your different requests.

UV-9000 series Double Beam UV Visible Spectrophotometer

1. Dual Beam Light Path
2. Powerful Stand-alone Operation System
3. Unique Long Light Path Design
4. Rigid Structure, 16mm-thick Optical Base
5. One-button Automatic Calibration System
6. 6 inches High-Definition Large LCD Display
7. Easy Data Output by USB/Parallel Port
8. Powerful Software Functions

X6 Single Beam/X8 series Double Beam UV Visible Spectrophotometer


1. Large HD Smart Touch Screen
2. Stand-Alone System with Multi Functions
3. Automatic 8-position Cell Holder
4. Easy Printing
5. USB Port, Fast Data Output
6. Optional Bluetooth Module and PC software.
7. Large Sample Chamber, Multi Options of Accessories
8. High-quality Grating with High Performance
9. 16mm-thick Optical Base, Rigid Structure
Comparison Table: UV-6000, UV-6100, and UV-9000 Series
ParameterUV-6000UV-6100 / 6100A / 6100SUV-9000 / 9000A / 9000S
Optical SystemSingle BeamSingle BeamDouble Beam (1200 Lines/mm Grating)
Wavelength Range190 - 1100nm190 - 1100nm190 - 1100nm
Bandwidth1.8nm

1.8nm (6100)


1nm (6100A)


0.5/1/2/4nm (6100S)

1.8nm (9000)


1nm (9000A)


0.5/1/2/4nm (9000S)

Wavelength Accuracy±0.5nm

±0.1nm @ 656.1nm


±0.3nm (Full Range)

±0.1nm @ D2 656.1nm


±0.3nm (Full Range)

Wavelength Repeatability≤0.2nm≤0.1nm0.1nm
Photometric Accuracy±0.3%T (0-100%T)±0.3%T (0-100%T)±0.2%T (0-100%T)
Photometric Repeatability≤0.1%T≤0.1%T (0-100%T)≤0.1%T (0-100%T)
Photometric Range-0.3 - 3A, 0-200%T-0.3 - 3A, 0-200%T-0.3 - 3A, 0-200%T
Stability≤0.001A/30min @ 500nm≤0.001A/30min @ 500nm≤0.0005A/h @ 250, 500nm
Stray Light≤0.05%T @ 220, 360nm≤0.05%T @ 220, 360nm≤0.03%T @ 220, 360nm
Light SourceW & D2 LampW & D2 LampW & D2 Lamp
DetectorSilicon PhotodiodeSilicon PhotodiodeSilicon Photodiode
Display320*240 Dots LCD320*240 Dots LCD320*240 Dots LCD
OutputUSB & Parallel PortUSB & Parallel PortUSB & Parallel Port
Power RequirementsAC 110/220V, 50/60HzAC 110/220V, 50/60HzAC 110/220V, 50/60Hz

Key Differentiators:

  • UV-9000 Advantage: This series features a Double Beam optical system, which significantly improves stability (0.0005A/h) and reduces stray light compared to the 6000 series.

  • Suffix Meanings:

    • Standard (No Suffix): Fixed 1.8nm bandwidth.

    • A Series: Fixed 1nm bandwidth for higher resolution.

    • S Series: Adjustable bandwidth (0.5/1/2/4nm), offering maximum flexibility for diverse research requirements.

  • Precision: Wavelength accuracy and photometric precision improve as you move from the 6000 to the 9000 series.



    Technical Comparison: X Series Spectrophotometers

ParameterX6X8X8AX8S
Optical SystemSingle BeamDouble BeamDouble BeamDouble Beam
Light SourceW & D2 LampW & D2 LampW & D2 LampW & D2 Lamp
Wavelength Range190 - 1100nm190 - 1100nm190 - 1100nm190 - 1100nm
Spectral Bandwidth1.8nm1.8nm1nm0.5/1/2/4nm (Adjustable)
Display7-inch Touch Screen10-inch Touch Screen10-inch Touch Screen10-inch Touch Screen
Wavelength Accuracy±0.5nm

±0.1nm @ D2 656.1nm


±0.3nm (Full Range)

±0.1nm @ D2 656.1nm


±0.3nm (Full Range)

±0.1nm @ D2 656.1nm


±0.3nm (Full Range)

Wavelength Repeatability≤0.2nm≤0.1nm≤0.1nm≤0.1nm
Photometric Accuracy±0.3%T (0-100%T)±0.3%T (0-100%T)±0.3%T (0-100%T)±0.3%T (0-100%T)
Photometric Range-0.3-3A, 0-200%T-0.3-3A, 0-200%T-0.3-3A, 0-200%T-0.3-3A, 0-200%T
Stability≤0.001A/h≤0.001A/h≤0.001A/h≤0.001A/h
Stray Light≤0.05%T≤0.05%T≤0.05%T≤0.05%T
Control ModeStand-alone / PCStand-alone / PCStand-alone / PCStand-alone / PC
Data OutputUSB / BluetoothUSB / BluetoothUSB / BluetoothUSB / Bluetooth
Power RequirementsAC 110/220VAC 110/220VAC 110/220VAC 110/220V

Core Upgrades of the X Series:

  • X8 Series Performance: Unlike the X6, the entire X8 line uses a Double Beam optical system and a larger 10-inch touch screen, providing superior stability and a better user interface.

  • Precision and Bandwidth:

    • X8A provides a narrower 1nm bandwidth for higher resolution.

    • X8S offers the most flexibility with four switchable bandwidths (0.5/1/2/4nm), making it ideal for specialized research applications.

  • Connectivity: Both series support modern data handling through USB and optional Bluetooth, allowing for easier data export and laboratory integration.


FAQs

1. What is the main difference between Single Beam and Double Beam systems?

Single beam models (UV-6000, UV-6100, X6) utilize one light path, while Double Beam models (UV-9000, X8 series) split the light into two paths. This allows for real-time compensation of light source fluctuations, resulting in superior stability and higher accuracy.

2. What do the suffixes "A" and "S" represent in your model numbers?

The suffixes indicate the bandwidth configuration:

  • Standard (No Suffix): Fixed 1.8nm bandwidth.

  • A Series: Fixed 1nm bandwidth for higher resolution.

  • S Series: Adjustable bandwidth (0.5/1/2/4nm) for versatile research requirements.

3. How does the optical base plate affect instrument performance?

The UV-9000 and X series feature a 16mm-thick rigid die-cast aluminum base (8mm for UV-6000). This heavy-duty structure ensures that all optical components remain perfectly aligned, promising long-term stability and resistance to external vibrations.

4. What is the wavelength range for these spectrophotometers?

All models in the UV and X series cover a broad wavelength range of 190nm to 1100nm, spanning the entire Ultraviolet and Visible light spectrum.

5. What type of light sources are used in these instruments?

Every model is equipped with a high-quality Tungsten Lamp (W Lamp) for visible light and a Deuterium Lamp (D2 Lamp) for UV light to ensure consistent performance across the full spectrum.

6. What are the advantages of the X Series compared to the UV Series?

The X Series is our "Smart" line, featuring high-definition touch screens (7-inch or 10-inch), an automatic 8-position cell holder, and built-in stand-alone operating systems for a more intuitive user experience.

7. Can I use the X Series without a computer?

Yes. The X Series features a powerful stand-alone system with a large touch screen, allowing you to perform complex functions directly on the instrument. PC software is available as an optional add-on for advanced data analysis.

8. Is wireless data transfer supported?

The X series supports fast data output via USB port and offers an optional Bluetooth module for wireless connectivity, making it easy to integrate into modern lab environments.

9. How stable are these instruments during long tests?

The UV-9000 series offers the highest stability at ≤0.0005A/h, while the X series and UV-6000 series maintain high performance at ≤0.001A/h.

10. What is the stray light specification for the high-end models?

The UV-9000 series leads with stray light levels at ≤0.03%T, ensuring high photometric linear accuracy even when testing samples with high absorbance.

11. Do the instruments support automatic calibration?

Yes, models like the UV-9000 include a one-button automatic calibration system to ensure the instrument is always operating at peak precision with minimal downtime.

12. Is PC software included with the spectrophotometers?

Multi-functional PC software is available as an option for all series, providing advanced tools for quantitative analysis, kinetics, and spectrum scanning.

13. Are there different sample holder options?

Yes, the X series features a large sample chamber and comes standard with an automatic 8-position cell holder, with various other accessories available to suit different sample types.

14. What are the power requirements for international use?

All models are designed for global compatibility, supporting AC 110/220V at 50/60Hz.

15. Can I request trial samples before placing a bulk order?

For commercial inquiries and quality evaluation, we offer trial samples of our equipment. Please contact our sales team to discuss the specific requirements for your application.