NEWMEEN
High-Performance Intelligent Wet Laser Particle Size Analyzer Winner2018
High-Performance Intelligent Wet Laser Particle Size Analyzer
Product Overview
The Winner2018 is a state-of-the-art, fully automatic analytical instrument designed for high-precision particle characterization in liquid suspensions. This model utilizes advanced laser diffraction principles and MIE scattering theory to deliver a true reflection of particle size distribution. By automating the entire testing cycle—from water supply and alignment to dispersion and cleaning—it provides a "one-key" operation that eliminates human error and maximizes laboratory efficiency.
Key Features
Fully Automated Intelligence: One-button operation for water supply, optical alignment, ultrasonic dispersion, bubble removal, and cleaning.
Integrated Dispersion Technology: Built-in mechanical stirring and ultrasonic treatment prevent secondary precipitation of large particles.
Precision Optical Alignment: Employs a 0.1-micron motion accuracy stepping motor to maintain optimal optical paths.
Unconstrained Free Fitting: Specialized software reflects the true distribution state without being limited by pre-set functions.
Self-Cleaning Window: Built-in ultrasonic self-cleaning technology extends the service life of optical components.
Advanced Optical Path: Converging light Fourier transform design improves resolution for submicron particles.
Fully Automated Intelligence: One-button operation for water supply, optical alignment, ultrasonic dispersion, bubble removal, and cleaning.
Integrated Dispersion Technology: Built-in mechanical stirring and ultrasonic treatment prevent secondary precipitation of large particles.
Precision Optical Alignment: Employs a 0.1-micron motion accuracy stepping motor to maintain optimal optical paths.
Unconstrained Free Fitting: Specialized software reflects the true distribution state without being limited by pre-set functions.
Self-Cleaning Window: Built-in ultrasonic self-cleaning technology extends the service life of optical components.
Advanced Optical Path: Converging light Fourier transform design improves resolution for submicron particles.
Technical Specifications
Feature Detailed Specification Model Name Winner2018 Measurement Principle Laser Diffraction / MIE Scattering Theory Size Range 0.1 µm – 450 µm Accuracy Error < 1% (Deviation of D50) Repeatability Error < 1% (Deviation of D50) Measurement Channels 80 PCS Laser Specification Semiconductor (λ=635nm, P>2MW) Laser Lifetime > 25,000 Hours Ultrasonic System 40KHz / 60W Agitator Speed 0 – 3000 RPM (Adjustable) Alignment System Full Automatic Test Speed < 2 mins (Classical test < 15s)
FAQs
What is the core measurement principle of the Winner2018?
It uses Laser Diffraction based on the advanced MIE scattering theory for full-range accuracy.
How does the instrument prevent measurement errors from human factors?
The smart operation mode automates all testing steps, ensuring consistency regardless of the operator.
Can it handle large particles that settle easily?
Yes, the fully built-in dispersion system and shortened pipelines prevent large particle sedimentation during circulation.
What is the benefit of the unconstrained free fitting technique?
It allows for the most accurate reflection of the actual particle distribution without being restricted by specific mathematical models.
How accurate is the automatic alignment system?
The system reaches a micro-motion accuracy of 0.1 microns, maintaining the best optical state automatically.
Does the sample window require frequent manual cleaning?
No, the built-in ultrasonic self-cleaning function reduces the need for manual replacement and cleaning.
What is the expected lifespan of the laser source?
The semiconductor laser is rated for a long service time exceeding 25,000 hours.
Can the measurement results be compared across different batches?
Yes, the software supports statistical comparative analysis to identify differences between samples or batches.
What reporting parameters are included?
Reports include particle size distribution tables and graphs, median diameter (D50), average diameter, and specific surface area.
What file formats can the test results be exported in?
The software supports exporting to BMP, Txt, Word, and Excel formats.
Is the instrument compliant with international standards?
Yes, it is designed to meet the ISO13320 executive standards for laser diffraction.
What industries typically use this analyzer?
It is widely used in metallurgy, chemical industries, pesticides, energy, environmental monitoring, and abrasives.
What is the core measurement principle of the Winner2018?
It uses Laser Diffraction based on the advanced MIE scattering theory for full-range accuracy.
How does the instrument prevent measurement errors from human factors?
The smart operation mode automates all testing steps, ensuring consistency regardless of the operator.
Can it handle large particles that settle easily?
Yes, the fully built-in dispersion system and shortened pipelines prevent large particle sedimentation during circulation.
What is the benefit of the unconstrained free fitting technique?
It allows for the most accurate reflection of the actual particle distribution without being restricted by specific mathematical models.
How accurate is the automatic alignment system?
The system reaches a micro-motion accuracy of 0.1 microns, maintaining the best optical state automatically.
Does the sample window require frequent manual cleaning?
No, the built-in ultrasonic self-cleaning function reduces the need for manual replacement and cleaning.
What is the expected lifespan of the laser source?
The semiconductor laser is rated for a long service time exceeding 25,000 hours.
Can the measurement results be compared across different batches?
Yes, the software supports statistical comparative analysis to identify differences between samples or batches.
What reporting parameters are included?
Reports include particle size distribution tables and graphs, median diameter (D50), average diameter, and specific surface area.
What file formats can the test results be exported in?
The software supports exporting to BMP, Txt, Word, and Excel formats.
Is the instrument compliant with international standards?
Yes, it is designed to meet the ISO13320 executive standards for laser diffraction.
What industries typically use this analyzer?
It is widely used in metallurgy, chemical industries, pesticides, energy, environmental monitoring, and abrasives.