Engineered for academic, biological, and analytical testing facilities consuming approximately 100 liters per day, this compact benchtop water purification system converts municipal tap water directly into Grade 3 pure water and high-purity deionized water. Designed as an energy-efficient alternative to replace traditional electric water distillers, the unit delivers an hourly output of 15 liters at 25°C and an instantaneous dispense flow of up to 2.0 liters per minute when connected to a pressurized storage reservoir.

Five-Stage Cascade Filtration Architecture The purification process employs a sequential PF+AC+RO+DI process train:

  • A sediment pre-filtration column (BCS-PP) removes suspended rust, dirt, and colloidal particles.

  • A two-stage carbon treatment pairing a granular activated carbon column (BCS-AC1) with an extruded carbon block column (BCS-AC2) adsorbs free chlorine, organic contaminants, and microorganisms.

  • A high-rejection 100 GPD reverse osmosis membrane removes up to 99% of dissolved inorganic ions and organic molecules above 200 Daltons.

  • Dual deionization purification columns (BCS-DI1) packed with high-capacity ion-exchange resins utilize a downflow configuration to prevent resin fluidization and stratification, delivering deionized water with a resistivity exceeding 15 MΩ·cm at 25°C, heavy metals below 0.1 ppb, and TOC levels under 30 ppb.

Intelligent Control, Automated Maintenance, and Ergonomics The system features a microcomputer controller with an animated LED display showing real-time operational status, including flushing, production, tank full, water shortage, and routine servicing alerts. To prevent mineral scaling on the membrane without chemical softeners, the unit executes three automated 30-second flush cycles: at startup, following water-shortage resets, and after every two hours of cumulative water generation. Consumable maintenance relies on a quick-turn rotary interface that enables column changeouts in tens of seconds without special tooling.


Technical Specifications

Specification CategoryParameter ItemTechnical Value / Description
System Process & FlowOverall Purification Process

PF + AC + RO + DI (5-stage cascade purification)

Stage 1 Pretreatment

BCS-PP pre-filtration column (1 piece)

Stage 2 Activated Carbon

BCS-AC1 granular activated carbon column (1 piece)

Stage 3 Carbon Block

BCS-AC2 extruded carbon rod column (1 piece)

Stage 4 Reverse Osmosis

BCS-RO-100GPD reverse osmosis membrane (1 piece)

Stage 5 Deionization

BCS-DI1 deionization purification columns (2 columns)

Feed Water LimitsRequired Water Source

Municipal tap water

Feed Water Electrical Conductivity

< 400 μS/cm (External softener recommended if > 400 μS/cm)

Operating Water Temperature

5°C – 45°C

Operating Inlet Pressure

1.0 – 4.0 kgf/cm²

Output CapacityContinuous Production Rate

15 Liters / hour (measured at 25°C, 50 psi, 15% recovery ratio)

Instantaneous Dispensing Rate

Up to 2.0 Liters / minute (with pressurized water tank)

Water Dispensing Outlets

Dual outlets: RO pure water and DI deionized water

RO Pure Water QualityElectrical Conductivity

≤ Feed water conductivity × 2%

Organic Compound Rejection Rate

> 99% (for organic molecules with MW > 200 Daltons)

Particles & Bacteria Removal Rate

> 99%

DI Water QualityElectrical Resistivity

> 15 MΩ·cm @ 25°C

Total Organic Carbon (TOC)

< 30 ppb

Heavy Metal Ion Content

< 0.1 ppb

Particulate Matter (> 0.22 μm)

N/A (requires optional point-of-use microfilter)

Bacterial Content

N/A (requires optional terminal sterile filter)

Monitoring & SafetyWater Quality Monitoring

Integrated online DI monitor; portable battery-powered TDS/temp meter

Visual & Audible Alarms

Self-test, power-off reset, limit alert, low/high-pressure & shortage protection

RO Membrane Anti-Scaling

Timed 30-second flushing: startup, shortage reset, and every 2h production

Electrical & PhysicalPower Supply & Power Draw

AC 220V, 50 Hz (wide range AC 100–240V, 50/60 Hz), 72W

Dimensions (H × W × D)

530 mm × 325 mm × 560 mm

Machine Net Weight

Approx. 18 – 20 kg

Ambient Operating Environment

Temperature: 5°C – 45°C; Relative Humidity: 20% – 80%

Standard Package Inclusions

Main unit, full consumable cartridge set, accessory kit, 12L pressure tank

Estimated Consumable Lifespan Overview

Consumable Part ModelFunctional Component NameStandard QuantityEstimated Service Life per Unit
BCS-PPPretreatment Purification Column1 piece

4 – 6 months

BCS-AC1Granular Activated Carbon Column1 piece

4 – 6 months

BCS-AC2Activated Carbon Rod Column1 piece

4 – 6 months

BCS-RO-100GPDReverse Osmosis Membrane1 piece

1 – 2 years

BCS-DI1Deionization Purification Column2 sticks

Approx. 1,000 Liters of deionized water

Frequently Asked Questions (FAQ)

1. What distinct water grades are provided by the two dispensing ports?

The system features two independent outlets: one delivering reverse osmosis (RO) Grade 3 pure water and a second delivering high-purity deionized (DI) water with resistivity > 15 MΩ·cm.

2. Which laboratory procedures can utilize the RO pure water outlet?

RO water is suited for general glassware washing, ultrasonic bath filling, feed supply for secondary ultrapure water polishers, microbiological media dilution, and routine reagent preparation.

3. What applications are recommended for the deionized (DI) water output?

DI water is recommended for flame atomic absorption spectrometry (FAAS), buffer synthesis, hydroponics, biochemical reagent compounding, and sensitive microbial culture preparation.

4. What are the feed tap water quality requirements for installation?

The system operates on municipal tap water at 5°C to 45°C and 1.0 to 4.0 kgf/cm² pressure, with conductivity below 400 μS/cm (hard water above 400 μS/cm requires a pre-softener).

5. How does the unit prevent membrane fouling and mineral scaling?

It incorporates three automated 30-second flushing sequences: at power initialization, upon recovery from feed water shortages, and automatically after every 2 hours of cumulative water production.

6. How quickly can operators replace depleted filter cartridges?

The pretreatment and deionization columns utilize a quick-twist rotary interface, allowing routine cartridge exchanges to be completed in tens of seconds without tools.

7. Why does the deionization stage use a full downflow column configuration?

The full downflow configuration prevents water channeling and resin bed fluidization, avoiding resin layer stratification and maximizing ion exchange efficiency.

8. What is the expected service lifespan of the internal consumables?

Pretreatment columns (PP, AC1, AC2) typically last 4 to 6 months, the RO membrane lasts 1 to 2 years, and the dual DI polishing columns yield roughly 1,000 liters of deionized water.

9. How is water quality monitored during operation?

The system provides integrated online resistivity monitoring for DI water, supplemented by a portable battery-operated meter for checking TDS and temperature across tap, RO, and DI lines.

10. What built-in safety interlocks and alarms protect the equipment?

The microcomputer system includes visual and audible alarms for startup self-testing, power interruption reset, operating limit alerts, raw water cutoffs, and low/high-pressure excursions.

11. How does this system compare to an electric laboratory water distiller?

Operating at just 72W power consumption, this system consumes over 95% less electricity than a thermal water still while producing higher purity water with lower maintenance overhead.

12. Can the purifier feed external laboratory equipment automatically?

Yes, pairing the unit with an external pressurized storage tank enables pressurized automated on-demand feed to automated glassware washers, autoclaves, and analytical analyzers.