NEWMEEN
Laboratory Syringe Pump TYD02-04
TYD02-04 High-Precision Laboratory Syringe Pump (4-Channel)
The TYD02-04 is an integrated table-model syringe pump designed for high-precision micro-transmission of various fluids in scientific research. Featuring a 5-inch HD LCD touch screen and a robust mechanical drive, it supports up to 4 channels simultaneously with a wide flow range from 0.184 nL/min to 24.520 mL/min.
Core System Features
• Intelligent Interaction:
• 5-inch HD Color Touch Screen: High-resolution display with an intuitive interface and animation showing operation status.
• Hybrid Operation: Combines touch screen control with mask keys and status indicator lights.
• Convenience Design: Supports screen locking, key mute operation, and adjustable display brightness.
• Precision Engineering:
• Aviation Bearing Screw Fixation: Utilizes high-strength aviation bearings for superior accuracy and significantly longer service life compared to traditional copper sleeves.
• High Resolution: Achieves a stroke resolution of 0.156 μm/ustep with a linear travel accuracy of <±0.35%.
• High Force Output: Provides a maximum rated linear force of >20 kgf with adjustable thrust (25%–100%).
• Versatile Operation:
• Five Working Modes: Includes Infuse, withdrawal, infuse/withdraw, withdraw/infuse, and continuous circulation.
• Syringe Compatibility: Built-in specifications for major manufacturers plus support for customized syringes via direct dimension input.
• Safety and Protection:
• Real-time Alarms: Includes a traffic jam alarm and syringe protection functions to ensure experimental safety.
• Reliability: Strong Anti-EMI performance ensures stable operation even under high-voltage electrostatic fields.
• Connectivity and Integration:
• Digital Communication: RS485 interface with MODBUS protocol for connection to PLCs, computers, or single-chip systems.
• External Control: Physically isolated signals for Start/Stop and Direction control.
Technical Specifications
Category Parameter Specification Number of Channels 4 Working Modes Infuse, withdrawal, infuse/withdraw, withdraw/infuse, continuous Flow Rate Range 0.184 nL/min ~ 24.520 mL/min Syringe Size Range 10 μL ~ 10 mL Maximum Stroke 140 mm Stroke Resolution 0.156 μm/ustep Linear Velocity 1 μm/min ~ 150 mm/min Max Rated Linear Force > 20 kgf (adjustable 25% ~ 100%) Control Accuracy Error < ±0.35% (when working stroke > 30% of whole stroke) External Control RS485 (MODBUS), WiFi (optional), Isolated Start/Stop/Direction Power Supply AC 100 ~ 240V, 50/60Hz IP Rating IP31 Dimensions / Weight 290 × 208 × 187.5 mm / 5.35 kg LCD Screen

Syringe Specifications & Flow Rate Reference
Syringe Size Syringe ID (mm) Min Flow Rate (nL/min) Max Flow Rate (mL/min) 10 µL 0.485 mm 0.184 nL/min 27.711 µL/min 25 µL 0.729 mm 0.417 nL/min 62.608 µL/min 50 µL 1.03 mm 0.833 nL/min 124.984 µL/min 100 µL 1.457 mm 1.667 nL/min 250.092 µL/min 250 µL 2.304 mm 4.169 nL/min 625.383 µL/min 500 µL 3.256 mm 8.326 nL/min 1.248 mL/min 1000 µL 4.608 mm 16.676 nL/min 2.501 mL/min 1 mL 4.699 mm 17.342 nL/min 2.60 mL/min 3 mL 8.585 mm 57.885 nL/min 8.682 mL/min 5 mL 11.989 mm 112.890 nL/min 16.933 mL/min 10 mL 14.427 mm 163.469 nL/min 24.520 mL/min Dimension (mm)

FAQ
1. How many syringes can this pump drive at once?
The TYD02-04 is a 4-channel pump, meaning it can drive up to 4 plastic or gas-tight syringes simultaneously.
2. What is the minimum and maximum flow rate achievable?
The flow rate ranges from 0.184 nL/min (with a 10 μL syringe) up to 24.520 mL/min (with a 10 mL syringe).
3. What is the benefit of the aviation bearing design?
The aviation bearings used for drive screw fixation offer higher accuracy and a significantly longer service life than traditional copper sleeves.
4. Can this pump be used in high-voltage environments?
Yes, it features strong Anti-EMI performance, allowing for stable operation even in high-voltage electrostatic fields.
5. Does it support syringes from different brands?
Yes, it has built-in specifications for major manufacturers and allows for "custom syringe" mode where you can manually input the syringe diameter.
6. What happens if the pump encounters a blockage?
The pump includes a traffic jam alarm function that alerts the user and ensures the safety of the experimental process.
7. Can I integrate this pump into an automated PLC system?
Yes, it supports RS485 communication and the MODBUS protocol, making it compatible with computers, PLCs, and single-chip computers.
8. Does the pump remember settings after power loss?
Yes, it features power-off memory which automatically stores running parameters.
9. What are the five available working modes?
The modes are: Infuse, withdrawal, infuse/withdraw, withdraw/infuse, and continuous circulation.
10. How precise is the liquid delivery?
The stroke resolution is 0.156 μm/ustep, with a linear travel accuracy error of less than ±0.35% (when using more than 30% of the stroke).
11. Is the screen display clear and informative?
Yes, the 5-inch color LCD displays transfusion volume, flow rate, operation direction, and syringe specifications with animation.
12. Is the thrust adjustable?
Yes, the maximum rated linear force is over 20 kgf, and the thrust regulation is adjustable from 25% to 100%.